Asset Management Toolkit (AMT)

Asset Management Toolkit (AMT)

Artesis AMT Toolkit is a portable motor driven equipment test system which automatically generates a condition assessment report indicating existing faults (both electrical and mechanical), time to failure information, recommended corrective actions, and effects of faults on energy efficiency. This unique instrument is capable of monitoring three phase AC motors and generators (as well as driven equipment) of all sizes and power levels to provide clear, unambiguous indications when the performance of a motor driven equipment begins to degrade. The toolkit uses three current sensors and three voltage sensors, making the system straightforward to install, and use without in-depth training of personnel. The test duration is approximately 30 minutes allowing 8- 12 tests to be performed in a day. Report is issued immediately at the end of the test.

Highlights

  • Immediate payback by corrective action
  • Instant condition assessment report
  • Advanced analysis and reporting
  • No sensors on motor or equipment
  • Improved efficiency and reliability of plant & processes
  • Increased machine availability

AMT

How It Works

Artesis AMT is equipped with a computer, a fully functional AES for AMT Software, current transformers, and cables. Artesis AMT is connected to motor cables using clamp on current sensors and voltage cables. It collects data from motor driven systems and saves them to the SQL database. At the end of the testing period, the toolkit generates a condition assessment report which indicates existing faults of the system, time to failure information, recommended corrective actions, and effects of these faults on energy efficiency.

Features

Fault Coverage

Fault Coverage

  • Loose Foundation/Components
  • Unbalance/Misalignment/Coupling
  • Transmission Faults
  • Driven Equipment Faults
  • Bearing Faults
  • Rotor Faults Stator/Insulation Faults
  • Voltage Unbalance
  • Current Unbalance
  • Internal And External Electrical Faults

Process Faults

  • High Energy Consumption
  • Low Efficiency
  • Cavitation In Pumps
  • Flow Turbulence In Fans, Blowers
  • Filter And Heat Exchanger Fouling
  • Lubrication
  • Oversize/Undersize Motors

Process Fault

Parameters

Parameters

  • Rms Values Of Three Phase Voltages And Currents
  • Frequency
  • Power Factor
  • Active Power
  • Reactive Power
  • Total Harmonic Distortion Harmonics Up To 13th
  • Voltage And Current Balances